NH-YJV XLPE MICE Cable
NH-YJV Fire Resistant Copper Conductor XLPE Insulated PVC Sheathed Power Cable
Model:
NH-YJV, ZCNH-YJV, WDZN-YJY, NH-YJV22
Other available series: YJV, ZC-YJV, WDZ-YJV, YJLV, etc., upon request.
Rated Voltage:
0.6/1 kV (standard)
Specification:
Single core: 1.5 mm² – 630 mm²
Multi-core: 1.5 mm² – 400 mm² (cores: 2, 3, 4, 5, 3+1, 3+2, 4+1)
Features:
NH-YJV offers excellent fire resistance, maintaining circuit integrity for a specified duration under fire conditions. Max. conductor operating temperature 90°C, short-circuit temperature 250°C, service life ≥30 years.
Application:
Suitable for fire-fighting equipment, emergency lighting, elevators, fire alarm systems and other circuits requiring continued power supply during fire. Can be installed in cable trays, conduits, tunnels; armoured type suitable for direct burial.
Model:
NH-YJV, ZCNH-YJV, WDZN-YJY, NH-YJV22
Other available series: YJV, ZC-YJV, WDZ-YJV, YJLV, etc., upon request.
Rated Voltage:
0.6/1 kV (standard)
Specification:
Single core: 1.5 mm² – 630 mm²
Multi-core: 1.5 mm² – 400 mm² (cores: 2, 3, 4, 5, 3+1, 3+2, 4+1)
Features:
NH-YJV offers excellent fire resistance, maintaining circuit integrity for a specified duration under fire conditions. Max. conductor operating temperature 90°C, short-circuit temperature 250°C, service life ≥30 years.
Application:
Suitable for fire-fighting equipment, emergency lighting, elevators, fire alarm systems and other circuits requiring continued power supply during fire. Can be installed in cable trays, conduits, tunnels; armoured type suitable for direct burial.
Category:
Product Details
| Type | Voltage | Construction |
| NH-YJV | 0.6/1 kV | Fire resistant copper conductor XLPE insulated PVC sheathed power cable (GB/T 12706.1, GB/T 19666) |
| ZCNH-YJV | 0.6/1 kV | Flame retardant and fire resistant copper conductor XLPE insulated PVC sheathed power cable (GB/T 19666) |
| WDZN-YJY | 0.6/1 kV | Low smoke zero halogen and fire resistant copper conductor XLPE insulated halogen-free polyolefin sheathed power cable (GB/T 19666) |
| NH-YJV22 | 0.6/1 kV | Fire resistant copper conductor XLPE insulated steel tape armoured PVC sheathed power cable (GB/T 12706.1, GB/T 19666) |
| Note: All above cables comply with IEC 60502-1. The IEC standard does not assign specific type numbers; Chinese type names are commonly used. Fire resistance meets the requirements of GB/T 19666 and relevant IEC 60331 standards. | ||
| Type | Voltage | Number of Cores | Nominal CSA (mm²) |
| NH-YJV | 0.6/1 kV | 1 | 1.5~630 |
| NH-YJV | 0.6/1 kV | 2 | 1.5~185 |
| NH-YJV | 0.6/1 kV | 3 | 1.5~400 |
| NH-YJV | 0.6/1 kV | 4, 5 | 1.5~300 |
| NH-YJV | 0.6/1 kV | 3+1, 3+2, 4+1 | 4~400 |
| ZCNH-YJV | 0.6/1 kV | same as above | same as above |
| WDZN-YJY | 0.6/1 kV | same as above | same as above |
| NH-YJV22 | 0.6/1 kV | same as above | same as above |
| Note: Higher voltage ratings and special fire resistant constructions available upon request. | |||