WDZAN-YJY Flame Retardant Cable
WDZAN-YJY Low Smoke Zero Halogen Flame Retardant Class A Fire Resistant Copper Conductor XLPE Insulated Polyolefin Sheathed Power Cable
Model:
WDZAN-YJY, WDZN-YJY, WDZAN-YJY23, WDZAN-YJLY
Other available series: WDZ-YJY, NH-YJV, ZC-YJV, etc., upon request.
Rated Voltage:
0.6/1 kV (standard)
Specification:
Single core: 1.5 mm² – 630 mm²
Multi-core: 1.5 mm² – 400 mm² (cores: 2, 3, 4, 5, 3+1, 3+2, 4+1)
Features:
WDZAN-YJY integrates low smoke zero halogen, Class A flame retardancy and fire resistance. It emits virtually no halogen acid gases or dense smoke when burning, and maintains circuit integrity under fire. Max. conductor temperature 90°C, short-circuit temperature 250°C, service life ≥30 years.
Application:
Suitable for fire protection and emergency power circuits in high-rise buildings, hospitals, subways, airports and other densely populated or critical facilities. Can be installed in cable trays, conduits, tunnels; armoured type can be directly buried.
Model:
WDZAN-YJY, WDZN-YJY, WDZAN-YJY23, WDZAN-YJLY
Other available series: WDZ-YJY, NH-YJV, ZC-YJV, etc., upon request.
Rated Voltage:
0.6/1 kV (standard)
Specification:
Single core: 1.5 mm² – 630 mm²
Multi-core: 1.5 mm² – 400 mm² (cores: 2, 3, 4, 5, 3+1, 3+2, 4+1)
Features:
WDZAN-YJY integrates low smoke zero halogen, Class A flame retardancy and fire resistance. It emits virtually no halogen acid gases or dense smoke when burning, and maintains circuit integrity under fire. Max. conductor temperature 90°C, short-circuit temperature 250°C, service life ≥30 years.
Application:
Suitable for fire protection and emergency power circuits in high-rise buildings, hospitals, subways, airports and other densely populated or critical facilities. Can be installed in cable trays, conduits, tunnels; armoured type can be directly buried.
Category:
Product Details
| Type | Voltage | Construction |
| WDZAN-YJY | 0.6/1 kV | Low smoke zero halogen flame retardant Class A fire resistant copper conductor XLPE insulated polyolefin sheathed power cable (GB/T 12706.1, GB/T 19666) |
| WDZN-YJY | 0.6/1 kV | Low smoke zero halogen flame retardant fire resistant copper conductor XLPE insulated polyolefin sheathed power cable (GB/T 12706.1, GB/T 19666) |
| WDZAN-YJY23 | 0.6/1 kV | Low smoke zero halogen flame retardant Class A fire resistant copper conductor XLPE insulated steel tape armoured polyolefin sheathed power cable (GB/T 12706.1, GB/T 19666) |
| WDZAN-YJLY | 0.6/1 kV | Low smoke zero halogen flame retardant Class A fire resistant aluminium conductor XLPE insulated polyolefin sheathed power cable (GB/T 12706.1, GB/T 19666) |
| Note: All above cables comply with IEC 60502-1. LSZH, flame retardant and fire resistant properties meet relevant IEC standards such as IEC 60754, IEC 61034, IEC 60332-3 and IEC 60331. The IEC standard does not assign specific type numbers; Chinese type names are commonly used. | ||
| Type | Voltage | Number of Cores | Nominal CSA (mm²) |
| WDZAN-YJY | 0.6/1 kV | 1 | 1.5~630 |
| WDZAN-YJY | 0.6/1 kV | 2 | 1.5~185 |
| WDZAN-YJY | 0.6/1 kV | 3 | 1.5~400 |
| WDZAN-YJY | 0.6/1 kV | 4, 5 | 1.5~300 |
| WDZAN-YJY | 0.6/1 kV | 3+1, 3+2, 4+1 | 4~400 |
| WDZN-YJY | 0.6/1 kV | same as above | same as above |
| WDZAN-YJY23 | 0.6/1 kV | same as above | same as above |
| WDZAN-YJLY | 0.6/1 kV | same as above | same as above |
| Note: Higher voltage ratings and special constructions available upon request. | |||